Troubleshooting¶
Common Issues and Resolutions¶
| Symptom | Possible cause | Resolution |
|---|---|---|
| Cameras do not charge | Dock has no power or the adapter is incompatible | Check the mains connection and use the supplied 24 VDC adapter or an approved replacement rated for at least 180 W. |
| One camera does not charge | Camera is not seated correctly or the USB-C connection is obstructed or damaged | Check that camera's seating and inspect its port and cradle connector. Keep connectors dry and clean; do not force a damaged connection. |
| Charging is slow or pauses | Temperature is outside the supported range or ventilation is obstructed | Check the dock's 0 C to 40 C operating range, keep ventilation openings clear, and review the camera's charging precautions. |
| No visible camera LED feedback | LED brightness settings or Covert mode suppress visible feedback | Check the camera display and see LED Status. |
| No cameras transfer recordings over Ethernet | Shared uplink cable, network connection, or switch link is faulty | Check dock power, the Ethernet cable, and the switch connection. All cameras use the same uplink. |
| One camera does not transfer recordings but others do | Affected camera has different docking, network, or integration settings | Check that camera's Enable Online Mode setting, Ethernet details, network access, and VMS or cloud integration. Shared uplink activity does not confirm that this camera is online. |
| Ethernet is connected but recordings do not transfer | Camera network access or receiving-system configuration is incorrect | Check each affected camera's network access and VMS or cloud integration. Inspect transfer jobs and errors in the receiving system. |
| Transfer is slower than expected | Shared network or receiving-system capacity is limited | Check the negotiated uplink, shared network traffic, and receiving-system performance. |
| Camera does not fit or seat correctly | Wrong camera model, obstruction, or connector damage | Do not force it. Confirm that the camera is a BC200, then inspect the cradle and connectors. |
For camera-specific power and startup checks, see BC200 Troubleshooting. For receiving-system configuration, use the Integration Guides.
Contact IONODES Support¶
- Phone: 450-696-1060 or 1-844-696-1060 (North America toll free).
- Email: support@ionodes.com.
- Web: Contact support.