Troubleshooting

Common Issues and Resolutions

Symptoms Possible cause Resolution
The encoder does not power up External power is disconnected or incompatible Check the supply connection and confirm compatibility with the device label. The original troubleshooting specification is 12 V, 40 W; confirm applicability to the unit before selecting a supply.
The encoder does not power up through PoE The network connection is not supplying power Verify that the RJ45 connection provides compliant PoE. A detected power source should light the status indicator.
The encoder is not yet discoverable after power-on Startup is still in progress Allow one to two minutes and wait for the ready state: steady yellow. See LED Status.
The encoder cannot be reached over the network The physical network link is unavailable Check the cable and switch connection. Verify that the green LED on the RJ45 connector is lit.
Bonjour discovery does not find the encoder Multicast delivery is unavailable Check multicast support on the network and switches, or use ICT unicast discovery. See Initial Setup.
The encoder has a 169.254.*.* address and cannot be reached remotely DHCP did not assign a suitable address Assign suitable TCP/IP settings through ICT. See Assign an IP Address.